YEAR 3    01-01-10 to 31-12-10

01-01-10 Cold day with bright sunshine. Pumping from early on. Hard to work out how much hot water is made on these days. But anything from the sun is welcome.

02-01-10 Cold day with bright sunshine. Pumping from early on.

03-01-10 Cold day with bright sunshine. Pumping from early on

04-01-10 Meter reading ( 0262 ) cm3 = ( 0049 ) = ( 549 kwh ) used this week. System is working well. Panel is freezing at night and controller goes into sleep mode. Then wakes up and starts pumping about 11AM. Battery keeping charged to about 12.8 volts. Even on a really cold day like today panel is getting up to 60C when the sun is shinning. Sky is very clear on these cold days. Made quite a lot of hot water today surprisingly. Pump was still going at 3PM. quite warm water coming out of the bottom of the cylinder.

05-01-10 Similar cold day but sun is hazy. Very little pumping.

06-01-10 Cold snowy day.

07-01-10 Cold snowy day.

08-01-10 Cold snowy day.

09-01-10 Cold snowy day.

10-01-10 Cold snowy day. Dread to think what the gas meter reading will be in the morning.

11-01-10 Cold overcast day. Meter reading ( 0321 ) cm3 = ( 0059 ) = ( 661 kwh ) used this week.

12-01-10 Dull cold day.

13-01-10 Dull cold day.

14-01-10 Dull day.

15-01-10 Hazy sunshine for a while. Controller wakes up after about a week ,but panel only gets up to 25C so no free hot water today.

16-01-10 Dull day.

17-01-10 Cold day with steady sunshine. Panel temp up to 75C. Made some hot water.

18-01-10 Cold overcast day. Meter reading ( 0368 ) cm3 = ( 0047 ) = ( 526 kwh ) used this week.

19-01-10 Cold overcast day.

20-01-10 Cold overcast day.

21-01-10 Out all day, but made some hot water, must have been sunny.

22-01-10 Dull day.

23-01-10 Dull day.

24-01-10 Dull day.

25-01-10 Dull day. Meter reading ( 0411 ) cm3 = ( 0043 ) = ( 482 kwh ) used this week.

26-01-10 Cold day then the sun comes out about 1 PM and there's pumping for about 2 hours.

27-01-10 Dull day.

28-01-10 Pumping for an hour around 1PM. Made some hot water.

29-01-10 Dull day.

30-01-10 Bright strong sunshine from early on. Panel soon up to 85C. Making a full tank of hot water today.

31-01-10 Bright strong sunshine. Made some hot water.

01-02-10 Bright strong sunshine from early on. Pump starts at 10 AM. Meter reading ( 0459 ) cm3 = ( 0048 ) = ( 538 kwh ) used this week. Made a full tank of hot water today.

02-02-10 Dull rainy day.

03-02-10 Dull rainy day.

04-02-10 Dull rainy day. Gas bill paid today 31-10-09 to 28-01-10 £ 188.25.

05-02-10 Mild but quite sunny day. Made quite a bit of hot water.

06-02-10 Mild sunny day. Made quite a bit of hot water.

07-02-10 Cold dull day.

08-02-10 Cold dull day. Meter reading ( 0498 ) cm3 Note new formula for kwh conversion = cm3 * 39.3368 * 1.0226400 / 3.6 = kwh. = ( 0039 ) = ( 435 kwh ) used this week.

09-02-10 Cold day with long sunny spells. Made some hot water.

10-02-10 Cold snowy day with long sunny spells. Made some hot water.

11-02-10 Freezing cold day with strong sunlight from 9AM. Cylinder is full with hot water by 1AM and pump is still going.

12-02-10 Made some hot water for a while.

13-02-10 Dull rainy day.

14-02-10 Dull rainy day.

15-02-10 Dull overcast day mostly. Some pumping. Not much. Meter reading ( 0545 ) cm3 = ( 0047 ) = ( 525 kwh ) used this week.

16-02-10 Heavy rain all day.

17-02-10 Nice sunny day. Pump going for several hours. Made a lot of hot water.

18-02-10 Dull day.

19-02-10 Dull day. Some sunny spells. Some pumping.

20-02-10 Cold frosty night, but bright sunny day. Made a full tank of hot water.

21-02-10 Dull day

22-02-10 Dull rainy day. Meter reading ( 0584 ) cm3 = ( 0039 ) = ( 435 kwh ) used this week.

23-02-10 Heavy rain all day.

24-02-10 Dull day mostly. A small amount of pumping.

25-02-10 Dull rainy day.

26-02-10 Sunny day just about. Pump starts at 10.30 PM till about 2PM.

27-02-10 Sunny spells. Some pumping throughout the day.

28-02-10 Dull rainy day

01-03-10 Meter reading ( 0623 ) cm3 = ( 0039 ) = ( 435 kwh ) used this week. Nice sunny day. Made a full tank of really hot water by 1PM.

02-03-10 Nice sunny day. Made a full tank of hot water. Pre-filled the washing machine 3 times.

03-03-10 Cold breezy chilly day. A few sunny spells. Made some hot water. Not much.

04-03-10 Cloudy and chilly to start off. Then sunny spells from 10.45 AM till 3 PM. Made some hot water.

05-03-10 Cold day, but bright sunshine. Pumping from 10 AM will make a full tank today.

06-03-10 Cold day, Hazy sunshine with some clear spells. Made some hot water.

07-03-10 Cold day. Bright sunshine. Pump going from 10.30 AM.

08-03-10 Meter reading ( 0663 ) cm3 = ( 0040) = ( 446 kwh ) used this week. Cold day with bright sunshine. Pump going from 9.30 AM.

09-03-10 Dull cold overcast day.

10-03-10 Dull cold overcast day with some pumping about 12 AM. Not much.

11-03-10 Dull cold overcast day.

12-03-10 Dull overcast day. Sun is trying to come out.

13-03-10 Sunny spells. Made some hot water.

14-03-10 Sunny spells. Made some hot water.

15-03-10 Meter reading ( 0698 ) cm3 = ( 0035 ) = ( 391 kwh ) used this week. Cold but sunny day. Pump started at 9 AM. Made a full tank of hot water.

16-03-10 Nice sunny day. List time this year I never had to put the boiler on this morning. Pump going from 9.30 AM . Made a full tank of hot water. Changed my gas and electricity tariff to Websaver6.

17-03-10 Nice sunny day. Pump going from 10 AM.

18-03-10 No boiler on this morning. Hazy sunshine. Pump going from 10 AM. Made some hot water.

19-03-10 Overcast dull day.

20-03-10 Dull rainy day.

21-03-10 Hazy sunshine. Pump started at 1 PM. Made some hot water.

22-03-10 Meter reading ( 0720 ) = ( 0022 ) = ( 245 kwh ) used this week. Sunny spells all day. Pump going from 9.30 AM.

23-03-10 Nice sunny morning. made some hot water. Hazy sunshine from 1 PM.

24-03-10 Hazy sunshine with sunny spells. Made some hot water.

25-03-10 Dull rainy day. Then the sun came out and the pump started at 11 AM

26-03-10 Long sunny spells all day. Making hot water.

27-03-10 Some sunny spells. Made some hot water.

28-03-10 Sunny spells. Made some hot water.

29-03-10 Meter reading ( 0741 ) = ( 0021 ) = ( 234 kwh ) used this week. Dull overcast day. Some pumping in the afternoon. Not much.

30-03-10 Dull day mostly. Some pumping in the afternoon. Not much.

31-03-10 Dull cold day.

01-04-10 Dull day with sunny spells. Some pumping. Not much.

02-04-10 Dull rainy day with sunny spells. Some pumping.

03-04-10 Dull day with sunny spells. Some pumping.

04-04-10 Still a bit cold with sunny spells. Some pumping.

05-04-10 Meter reading ( 0775 ) = ( 0034 ) = ( 379 kwh ) used this week. Dull windy day with sunny spells. Some pumping.

06-04-10 Nice warm sunny day. A bit hazy. Pumping from early on. System working well.

07-04-10 Dull rainy day.

08-04-10 Really nice sunny day. Pumping from early on. Made a full tank of hot water.

09-04-10 Really nice sunny day. Pumping from early on. Made a full tank of hot water by 1PM.

10-04-10 Nice sunny day. Pumping from early on.

11-04-10 Nice sunny day. Pumping from 9.30 AM. Plenty of free hot water.

12-04-10 Meter reading ( 0789 ) = ( 0014 ) = ( 156 kwh ) used this week. A bit chilly with hazy sunshine. Pump going from 9.30 AM.

13-04-10 Nice hazy sunny day. Pump going from 9 AM.

14-04-10 Hazy overcast day. Sun comes out about 2 PM and fills the tank with hot water for an hour or so.

15-04-10 Hazy sunshine. Pump going from 10 AM. Making steady hot water. Not an Airplane in the sky.

16-04-10 Chilly day with long spells of hazy sunshine. Pump going from 10 AM. Will make a full tank today.

17-04-10 Really nice sunny day. Pump going from early on. Making a lot of free hot water.

18-04-10 Really nice sunny day. Making a lot of hot water.

19-04-10 Meter readings ( 0803 ) = ( 0014 ) = ( 156 kwh ) used this week. Day starts off dull, then the sun comes out and the pump starts from 10 am. Making a full tank of hot water.

20-04-10 A bit chilly, but long sunny spells. Pump going from 9 AM.

21-04-10 Chilly day again, but long sunny spells. Pump gong from 9 AM. Made a full tank of really hot water by 3PM.

22-04-10 Same thing again just about.

23-04-10 Same thing again.

24-04-10 Same thing again, but warmer. Chill gone.

25-04-10 Nice sunny day. Pump going all day.

26-04-10 Meter reading. ( 0815 ) = ( 0012 ) = ( 134 kwh ) used this week.

27-04-10 A bit hazy, but pump going all day. Making hot water.

28-04-10 Same thing again.

29-04-10 Hazy sunshine, pump going all day.

30-04-10 Same thing again

01-05-10 Quite hot sunshine. Pump going up till 4 PM.

02-05-10 Dull rainy day.

03-05-10 Meter reading. ( 0824 ) = ( 0009 ) = ( 100 kwh ) used this week. Cold again, with sunny spells. Made some hot water.

04-05-10 Not very warm, but long sunny spells. Made some hot water.

05-05-10 Still a bit cold, but long sunny spells. Making quite a bit of hot water. Having to put the boiler on in the evenings to warm the house up a bit.

06-05-10 Election day. Nice sunny day. Pump going from 9.30 AM. Made a full tank.

07-05-10 Sunny start. pump going up till 1.30 AM.

08-05-10 Dull overcast day.

09-05-10 Dull overcast day.

10-05-10 Meter reading. ( 0845 ) = ( 0021 ) = ( 234 kwh ) used this week. Gas bill £ 143.36 Excluding VAT. Chilly , but sunny. Pump going from 9.30 AM.

11-05-10 Sunny spells. Some pumping.

12-05-10 Sunny spells. Some pumping.

13-05-10 Long sunny spells all day made hot water.

14-05-10 Chilly with long sunny spells. Making hot water all day.

15-05-10 Chilly with long sunny spells. Making hot water all day.

16-05-10 Dull then sunny then heavy rain. Made some hot water.

17-05-10 Meter reading. ( 0860 ) = ( 0015 ) = ( 167 kwh ) used this week. Cloudy with long sunny spells. Made hot water most of the day.

18-05-10 Cloudy with long sunny spells. Made some hot water.

19-05-10 Warm muggy day with long sunny spells. Made a full tank. No need for the boiler at all.

20-05-10 Nice sunny day. Making lots of free hot water all day.

21-05-10 Hot sunny day. Making lots of free hot water.

22-05-10 Hot sunny day. Making lots of free hot water.

23-05-10 Scorching hot day. Made loads of free hot water.

24-05-10 Meter reading. ( 0862 ) = ( 0002 ) = ( 22 kwh ) used this week. Hot sunny day. Making hot water from 9 AM.

25-05-10 Cooler today, but sunny. Making plenty of hot water.

Using the formula: 1 cm3 = 1 * 39.3368 * 1.0226400 / 3.6 = 11.17 kwh

1 cm3 = 11.17 kwh

2 cm3 = 22.34 kwh

3 cm3 = 33.53 kwh

4 cm3 = 44.69 kwh

5 cm3 = 55.87 kwh

6 cm3 = 67.04 kwh

7 cm3 = 78.21 kwh

8 cm3 = 89.39 kwh

9 cm3 = 100.56 kwh

10 cm3 = 111.74 kwh

26-05-10 Cool day with long sunny spells. Made plenty of hot water.

27-05-10 A bit warmer with steady heat coming from the panel all day.

28-05-10 Warm day with long sunny spells. Pump going from 9.15 AM.

29-05-10 Dull rainy overcast day. Some pumping about 3PM, not much.

30-05-10 Dull overcast day. Some pumping. Not much. Blue tits left the nest-box today. Crow got one within minutes.

31-05-10 Meter reading ( 0866 ) = ( 0004 ) = ( 44 kwh ) used this week . Dull overcast day.

01-06-10 Dull rainy day.

02-06-10 Nice hot sunny day. Pump going all day.

03-06-10 Nice hot sunny day. Pump going all day.

04-06-10 Nice hot sunny day. Pump going all day. Making loads of free hot water.

05-06-10 Nice hot sunny day. Pump going all day.

06-06-10 Cloudy with showers most of the day. Some pumping in the afternoon.

07-06-10 Meter reading ( 0870 ) = ( 0004 ) = ( 44 kwh ) used this week. Cloudy overcast day, but quite strong infra red keeping the pump going on and off most of the day.

08-06-10 Dull and rainy to start, then sunny from 11 am. Pump going most of the day.

09-06-10 Sunny spells some pumping.

10-06-10 Dull overcast day.

11-06-10 Dull overcast day.

12-06-10 Sunny spells some pumping.

13-06-10 Sunny spells some pumping.

14-06-10 Meter reading ( 0873 ) = ( 0003 ) = ( 33kwh ) used this week. Hot sunny spells with steady pumping.

15-06-10 Chilly day with long sunny spells. Made hot water most of the day.

16-06-10 Nice sunny day. Made hot water all day.

17-06-10 Nice sunny day. Made hot water all day.

18-06-10 Dull overcast day. Some pumping.

19-06-10 Dull overcast day. Panel still getting quite hot. Some pumping .

20-06-10 Dull overcast day. Panel still getting quite hot. Some pumping all day.

21-06-10 Meter reading ( 0874 ) = ( 0001 ) = ( 11kwh ) used this week. Sunny spells all day. Making steady hot water. The longest day today.

22-06-10 Scorcher

23-06-10 Scorcher

24-06-10 Scorcher

25-06-10 A bit cloudy with long sunny spells. Pump going all day.

26-06-10 Scorcher

27-06-10 Scorcher

28-06-10 Meter reading ( 0875 ) = ( 0001 ) = ( 11 kwh ) used this week. Hot sunny day. Pump going from 9 AM.

29-06-10 Scorcher. Pump going all day.

30-06-10 Long sunny spells. Pump going all day.

01-07-10 Not so sunny, but hot. Pump going all day.

02-07-10 Scorcher. Pump going all day.

03 07-10 A bit overcast, but very warm. Pump going all day.

04-07-10 Pump going all day.

05-07-10 Meter reading ( 0876 ) = ( 0001) = ( 11 kwh ) used this week. Pump going all day.

06-07-10 Pump going all day.

07-07-10 Pump going all day. Using very little gas at the moment. Just for cooking.

08-07-10 Hot sunny day. Hottest yet.

09-07-10 Hot sunny day.

10-07-10 Hot sunny day.

11-07-10 Not so hot, but pump going all day.

12-07-10 Meter reading ( 0876 ) = ( 0000 ) = ( 0 kwh ) used this week. Not so hot, but pump going all day.

13-07-10 Overcast day. Some pumping.

14-07-10 Overcast with sunny spells. Some pumping.

15-07-10 Overcast with sunny spells. Some pumping.

16-07-10 Overcast with long sunny spells. Some pumping. Gas bill £ 34.30. Not bad.

17-07-10 Overcast with long sunny spells. Some pumping all day.

18-07-10 Nice sunny day. Pump going all day.

19-07-10 Meter reading ( 0878 ) = ( 0002 ) = ( 22 kwh ) used this week. Hot sunny day. Pump going all day.

20-07-10 Really warm sunny day. Pump going all day.

21-07-10 Really warm sunny day. Pump going all day.

22-07-10 Really warm sunny day. Pump going all day.

23-07-10 Slow start, then warm sunny day. Pump going from 11 AM.

24-07-10 Slow start, then hot sunny day. Pump going all day.

25-07-10 Hot sunny spells all day.

26-07-10 Meter reading ( 0879 ) = ( 0001 ) = ( 11 kwh ) used this week. Pump going all day.

27-07-10 Hot muggy day. Pump going even when the suns not out.

28-07-10 Hot sunny day. Pump going all day.

29-07-10 Nice sunny day. Pump going all day.

30-07-10 Sunny spells. Pumping nearly all day.

31-07-10 Sunny spells. pumping nearly all day.

01-08-10 Nice sunny day.

02-08-10 Meter reading ( 0880 ) = ( 0001 ) = ( 11 kwh ) used this week. Sunny spells. Pump going all day.

03-08-10 Sunny day. Pump going from 9 AM.

04-08-10 Sunny then rain. Some pumping early on.

05-08-10 Long sunny spells then overcast. Some pumping most of the day.

06-08-10 Overcast with sunny spells. Some pumping.

07-08-10 Overcast with sunny spells. Some pumping.

08-08-10 Nice warm sunny day. Pump going all day.

09-08-10 Meter reading ( 0882 ) = ( 0002 ) = ( 22 kwh ) used this week. Sunny spells all day.

10-08-10 Overcast with rain and sunny spells. Some pumping.

11-08-10 Overcast with long sunny spells. Pumping from 10 AM.

12-08-10 Overcast with sunny spells. Some pumping.

13-08-10 Heavy rain with long sunny spells. Some pumping.

14-08-10 Overcast, but pump going from 11 AM. All black objects quite warm.

15-08-10 Mostly overcast with some long sunny spells. A lot of showers had today , but may get the water temp back up with some sunshine this afternoon.

16-08-10 Meter reading ( 0884 ) = ( 0002 ) = ( 22 kwh ) used this week. All these overcast days means I have to put the boiler from time to time for hot water. Overcast again today. The sun came about 1 PM really hot, and boosted things up quite nicely.

17-08-10 Dull overcast day. Nothing doing.

18-08-10 Decided to buy a new pump from Thailand VIA EBAY £26.44 See 12 volt water pump.

Sunny spells from 9 AM, then overcast, then sunny spells. Some pumping all day.

19-08-10 Dull sunny day. Some pumping all day.

20-08-10 Sunny spells. Some pumping all day.

21-08-10 On holiday.

22-08-10 H

23-08-10 H

24-08-10 H

25-08-10 H

26-08-10 H

27-08-10 H

28-08-10 Back today to a full tank of hot water. New pump waiting at the sorting office.

29-08-10 Mostly overcast with a few sunny spells then showers.

30-08-10 Meter reading ( 0886 ) = ( 0002 ) = ( 22kwh ) used this last two weeks.

The system has worked faultlessly for two years up to today. And it's a nice sunny day today. Pump going well.

31-08-10 New pump arrived today. Cloudy with long hot sunny spells. Pump going like mad all day just about. Fitted the new pump this evening when sun went in see link to 12 volt water pump

01-09-10 Really hot day. Had a minor disaster messing about with a new pump. Had to put the old pump back about 4 PM , and it made a full tank of hot water in about two hours. What a panic, thought I had melted the panel and temp probe at one point. All OK now.

02-09-10 Really nice sunny day. Pump going all day. Put some better clips on the pump connections. Now I can see how powerful it is.

03-09-10 Nice sunny day. Pump going all day.

04-09-10 Nice sunny day. Pump going all day.

05-09-10 Meter reading ( 0887 ) = ( 0001 ) = ( 11kwh ) used this week. Dull rainy day.

06-09-10 Sunny spells then rain. Some pumping.

07-09-10 Hot sunny spells with showers. Quite a bit of pumping.

08-09-10 Dull overcast day. Some pumping. Not much.

09-09-10 Nice sunny day. Pump going all day.

10-09-10 Overcast with some long sunny spells. Quite a bit of pumping.

11-09-10 Overcast with long sunny spells. Some pumping.

12-09-10 Nice sunny day. A bit cloudy. A lot of pumping today.

13-09-10 Meter reading ( 0890 ) = ( 0003 ) = ( 33kwh ) used this week.

14-09-10 Dull windy rainy day. Nothing doing.

15-09-10 Dull windy with sunny spells. Some pumping.

16-09-10 Dull windy with sunny spells. Some pumping.

17-09-10 A bit colder with long sunny spells. Pumping most of the day.

18-09-10 Nice sunny day. Pump going most of the day.

19-09-10 Sunny morning with some pumping. Dull overcast afternoon.

20-09-10 Meter reading ( 0895 ) = ( 0005 ) = ( 55kwh ) used this week. Mild day with long sunny spells. pump going most of the day.

21-09-10 Nice sunny day. Pump going up till 5 PM . A few overcast spells.

22-09-10 Nice sunny September day. Pump going all day. Not many more like this.

23-09-10 Dull rainy day. Nothing doing. Had to put the boiler on.

24-09-10 Dull rainy day.

25-09-10 A bit chilly, but sunny. Pump going most of the day.

26-09-10 Dull rainy day. Nothing doing.

27-09-10 Meter reading ( 0901 ) = ( 0006 ) = ( 66 kwh ) used this week. Dull rainy day.

28-09-10 Dull rainy day.

29-09-10 Dull overcast day.

30-09-10 Dull overcast day.

01-10-10 Dull rainy day.

02-10-10 Started off sunny with quite a bit of pumping. Then clouded over.

03-10-10 Dull rainy day.

04-10-10 Meter reading ( 0910 ) = ( 0009 ) = ( 99 kwh ) used this week. Dull rainy day.

05-10-10 Dull rainy day.

06-10-10 Dull rainy morning with nice sunny afternoon. Some pumping.

07-10-10 Sunny spells all day. Quite a bit of pumping. Cold caller at the door tries to sell me a solar hot water system for £7000.

08-10-10 Overcast most of the day. Some pumping.

09-10-10 Long sunny spells. Some pumping throughout the day.

10-10-10 Nice sunny day. Pumping all day.

11-10-10 Meter reading ( 0917 ) = ( 0007 ) = ( 77 kwh ) used this week. A nip in the air, But strong sun all day. Panel up to 90C on a day like today. Perfect solar hot water day.

12-10-09 Not quite so warm, but a good sunny day. Some pumping all day.

13-10-10 Turned colder and overcast. Nothing doing.

14-10-10 Dull overcast day.

15-10-10 Dull overcast day. Gas bill ( £30.73 ) Total gas bill for the year = £ 400.94

16-10-10 Sunny spells all day some pumping.

17-10-10 Long sunny spells all day. Pump going. Cold in the evening had to put the boiler on.

18-10-10 Meter reading ( 0929 ) = ( 0012 ) = ( 132 kwh ) used this week. A bit dull with some sunny spells. Some pumping.

19-10-10 Sunny spells and showers. Not much doing.

20-10-10 Cold frosty start, but strong sunshine all day. Pump going mad. Bonus solar day.

21-10-10 Cold frosty start, with sunshine all day. A lot of pumping.

22-10-10 Mostly dull rainy day with a few sunny spells. Some pumping.

23-10-10 Heavy rain to start with a few sunny spells later. Not much doing.

24-10-10 Chilly start with bright sunshine. Pump going from early on. A good solar day.

25-10-10 Meter reading ( 0946 ) = ( 0017 ) = ( 187 kwh ) used this week. Another bonus day. Really cold start with brilliant sunshine. Pump going all day.

26-10-10 Dull rainy day.

27-10-10 Cloudy to start with. A few sunny spells. Not much.

28-10-10 Cloudy to start with. A few sunny spells.

29-10-10 Dull overcast day. Purchased another new pump. see link to 12 volt water pump

30-10-10 Nice sunny day on and off. Pump going all day.

31-10-10 Dull rainy day

01-11-10 Meter reading ( 0965 ) = ( 0019 ) = ( 209 kwh ) used this week. Fitted new pump ( pump NO 3 ). Dull start then sun comes out about 12.30 AM. Dull sunshine throughout the afternoon. Some pumping.

02-11-10 Dull day with a bit of weak sunshine. Not much doing.

03-11-10 Sunny day, but sun hazy. Not much doing.

04-11-10 Week sunny spells. Some pumping. Not much.

05-11-10 Dull rainy day.

06-11-10 About 3 hours intermittent sub shine. Some pumping. Not much.

07-11-10 About 2 hours patchy sunshine. Some pumping.

08-11-10 Meter reading ( 0980 ) = ( 0015 ) = ( 165 kwh ) used this week. High winds and heavy rain all day.

09-11-10 Dull rainy day.

10-11-10 Dull rainy day.

11-11-10 Dull rainy day.

12-11-10 Dull rainy day. British gas prices to increase by 7% soon.

13-11-10 Dull overcast day.

14-11-10 Dull overcast day.

15-11-10 Meter reading ( 1013 ) = ( 0033 ) = ( 363 kwh ) used this week. Dull overcast day.

16-11-10 Freezing cold night. Panel must have frozen solid. New pump started at about 10.30 AM. All working OK.

17-11-10 Dull cold day.

18-11-10 Dull start then sunny for a while, then dull again.

19-11-10 Steady but weak sunshine all day. Some pumping.

20-11-10 Dull overcast day.

21-11-10 Dull overcast day.

22-11-10 Meter reading ( 1046 ) = ( 0033 ) = ( 363 kwh ) used this week. Dull overcast day.

23-11-10 Dull overcast day.

24-11-10 Cold frosty start, then sunny for about 4 hours. Some pumping. Hard to say how much hot water you make on a day like today.

25-11-10 Dull overcast cold day.

26-11-10 Really cold night, panel must have froze solid, but know the suns out and the sky is clear.

pump going like mad. Working on anti-freeze setup for the pump.

FROST PROOF PUMP HOUSING

27-11-10 Cold dull day.

28-11-10 Cold dull day.

29-11-10 Meter reading ( 1094 ) = ( 0048 ) = ( 528 kwh ) used this week. Dull cold day - 3C.

30-11-10 Cold snowy day. Panel must be frozen solid.

01-12-10 Cold snowy day. Panel frozen.

02-12-10 Cold snowy day. Panel frozen.

03-12-10 Cold snowy day. Panel frozen.

04-12-10 Dull day. A bit warmer, but no sun.

11-12-10 Dull day. Quite a bit warmer, but no sun.

12-12-10 Dull overcast day. A bit colder.

13-12-10 Meter reading ( 1187 ) = ( 0044 ) = ( 484 kwh ) used this week. Really cold night then weak hazy sunshine.

14-12-10 Dull cold day.

15-12-10 Dull cold day.

16-12-10 Dull rainy day. Nothing doing.

17-12-10 Snow then hazy sunshine.

18-12-10 Heavy snow.

19-12-10 Freezing cold day. Snow on the ground. Panel must be frozen.

20-12-10 Meter reading ( 1238 ) = ( 0051 ) = ( 561kwh ) used this week. Freezing cold day - 5 C this morning. Panel frozen.

21-12-10 The shortest day of 1010. Thawing, but cold. No sun.

22-12-10 Cold dull day.

23-12-10 Cold dull day.

24-12-10 Cold sunny day, but not sunny enough.

25-12-10 Cold dull day.

26-12-10 Cold day with sunny spells. Some pumping. Not much.

27-12-10 Meter reading ( 1288 ) = ( 0050 ) = ( 550kwh ) used this week. Cold dull day.

28-12-10 Cold dull day.

29-12-10 Much milder today, but overcast.

30-12-10 Dull overcast day.

31-12-10 Dull overcast day.

YEAR 4   01-01-11 to 31-12-13

BACK TO YEAR 1

BACK TO SOLARFRIEND